Diamond Anvils

The tables below gives you an overview of the applications, the anvil design and its characteristics

Experimental Technique Diamond Type Characteristics
Raman Spectroscopy & Related Vibrational Techniques

IR Spectroscopy

Fluorescence – Photoluminescence – X-ray Spectrometry

Electrical – Magnetic – Mössbauer

Type IIas – Raman ultra-low fluorescence & low birefringence ~1 ppm of nitrogen – white
Fluorescence – Photoluminescence – Xray Spectrometry

Electrical – Magnetic – Mössbauer

Type Ia ~2×10³ ppm of nitrogen – white to light yellow
Raman Spectroscopy & Related Vibrational Techniques

IR Spectroscopy

Fluorescence – Photoluminescence – X-ray Spectrometry

Electrical – Magnetic – Mössbauer

Pressures > 200 GPa

Type IIam – Raman ultra-low fluorescence & low birefringence

Raman edge > 200 GPa

~1 ppm of nitrogen – white
EXAFS NPD 50 – 100 ppm of nitrogen – yellow
Design Characteristics
Boehler-Almax design Conical crown design offering superior mechanical stability.
Smaller anvil reducing beam absorption.
Tungsten carbide seat with large aperture for diffracted patterns and signal.
Used in the following DACs: Plate DAC, Braggs (Plus), Bragg Mini and HeliosDAC Plus.
Diacell design Force-fitted into anvil rings for mechanical stability, ease of replacement and cryogenic use.
Design and dimensions optimised using FEA for most Diacell® DACs
(μScopeDACs, LeverDACs, CryoDACs, OmniDACs, Braggs (Be seat), HeliosDAC).
Standard design Thick girdle and large table to withstand the hightest pressures.
All dimensions are exact and consistent.
Optimum mechanical strength.
Modified Brilliant Cut  Low cost alternative.
Variation from traditional round brilliant cut.
Boehler-Almax Design
Diacell Design
Standard Design
Modified Brilliant Cut Design
Partial Perforation
Patterning
NPD
Mini and Maxi Diamond Anvils
Mini and Maxi

Boehler-Almax design

  • Type IIas, Boehler-Almax Design, X=3.30 mm, 85 deg, P01929

    Boehler-Almax, 3.30 mm - 85°

  • Type Ia; Boehler-Almax Design; X=3.30 mm, 85 deg, P00539

    Boehler-Almax, 3.30 mm - 85°

  • Type IIas; Boehler-Almax Design; X=3.10 mm, 70 deg, P01928

    Boehler-Almax, 3.10 mm – 70°

  • Type Ia; Boehler-Almax Design; X=3.10 mm, 70deg, P01036

    Boehler-Almax, 3.10 mm - 70°

  • Type IIas; Boehler-Almax Design; X=2.50 mm, 50 deg, P01927

    Boehler-Almax, 2.50 mm - 50°

  • Type Ia; Boehler-Almax Design; X=2.50 mm, 30 deg, P01035

    Boehler-Almax, 2.50 mm - 30°

  • Type IIas; Boehler-Almax Design; X=4.00 mm, 80 deg, P01931

    Boehler-Almax, 4.00 mm - 80°

  • Type Ia; Boehler-Almax Design; X=4.00 mm, 80 deg, P01039

    Boehler-Almax, 4.00 mm - 80°

  • Type IIas; Boehler-Almax Design; X=4.00 mm, 120 deg, P02201

    Boehler-Almax, 4.00 mm - 120°

  • Type Ia; Boehler-Almax Design; X=4.00 mm, 120 deg, P01848

    Boehler-Almax, 4.00 mm - 120°

  • Type IIas; Boehler-Almax Design; X=3.30 mm, 70 deg, P01930

    Boehler-Almax, 3.30 mm - 70°

  • Type Ia; Boehler-Almax Design; X=3.30 mm, 70 deg, P01037

    Boehler-Almax, 3.30 mm - 70°

  • Type IIas; Boehler-Almax Design; X=3.30 mm, 85deg, P02414

    Boehler-Almax, 3.30 mm - 85°

  • Type Ia; Boehler-Almax Design; X=3.30 mm, 85 deg, P02413

    Boehler-Almax, 3.30 mm - 85°

  • Type IIac, Boehler-Almax Design; X=3.30 mm, 85 deg, P01066

    Boehler-Almax, 3.30 mm - 85°

  • Type IIac; Boehler-Almax Design; X=3.10 mm, 70 deg, P01064

    Boehler-Almax, 3.10 mm - 70°

  • Type Ilac; Boehler-Almax Design; X=2.50 mm, 50 deg, P01063

    Boehler-Almax, 2.50 mm – 50°

  • Type IIac; Boehler-Almax Design; X=3.30 mm, 70 deg, P01065

    Boehler-Almax, 3.30 mm - 70°

  • Type IIac; Boehler-Almax Design; X=4.00 mm, 80 deg, P01067

    Boehler-Almax, 4.00 mm - 80°

Diacell design

  • Type IIas Diacell® design – P01933

    2.50 mm Diacell Design

  • Type Ia Diacell® design – P00131

    2.50 mm Diacell Design

  • Type IIas Diacell® design – P01934

    3.10 mm Diacell Design

  • Type Ia Diacell® design – P00132

    3.10 mm Diacell Design

  • Type IIas Diacell® design – P01932

    2.00 mm Diacell Design

  • Type Ia Diacell® design – P00130

    2.00 mm Diacell Design

  • Type IIac Diacell® design – P00134

    2.50 mm Diacell Design

  • Type IIac Diacell® design – P00135

    3.10 mm Diacell Design

  • Type IIac Diacell® design – P00133

    2.00 mm Diacell Design

Standard design

  • Type IIas Standard design – P01938

    3.25 mm Standard Design

  • Type Ia Standard design – P01006

    3.25 mm Standard Design

  • Type IIas Standard design – P01939

    3.50 mm Standard Design

  • Type Ia Standard design – P01007

    3.50 mm Standard Design

  • Type IIas Standard design – P01937

    3.00 mm Standard Design

  • Type IIas Standard design – P01935

    2.50 mm Standard Design

  • Type Ia Standard design – P01005

    3.00mm Standard Design

  • Type Ia Standard design – P01003

    2.50 mm Standard Design

  • Type IIas Standard design – P01940

    3.75 mm Standard Design

  • Type IIas Standard design – P01936

    2.75 mm Standard Design

  • Type Ia Standard design – P01008

    3.75 mm Standard Design

  • Type Ia Standard design – P01004

    2.75 mm Standard Design

  • Type IIas Standard design – P01941

    4.00 mm Standard Design

  • Type IIac Standard design – P01043

    3.25 mm Standard Design

  • Type IIac Standard design – P01045

    3.75 mm Standard Design

  • Type IIac Standard design – P01042

    3.00 mm Standard Design

  • Type IIac Standard design – P01040

    2.50 mm Standard Design

  • Type IIac Standard design – P01041

    2.75 mm Standard Design

  • Type IIac Standard design – P01044

    3.50 mm Standard Design

  • Type IIac Standard design – P01046

    4.00 mm Standard Design

Modified Brilliant Cut Design

  • Type Ia Modified Brilliant {Any} – P01253

    Y=3.75 mm, ~ 0.20 ct

  • Type Ia Modified Brilliant {100} – P01029

    Y=3.50 mm, ~ 0.15 ct

  • Type Ia Modified Brilliant {100} – P01030

    Y=3.75 mm, ~ 0.20 ct

  • Type Ia Modified Brilliant {Any} – P01252

    Y=3.50 mm, ~ 0.15 ct

  • Type Ia Modified Brilliant {100} – P01032

    Y=4.10 mm, ~ 0.25 ct

  • Type Ia Modified Brilliant {Any} – P01251

    Y=3.00 mm, ~ 0.10 ct

  • Type Ia Modified Brilliant {Any} – P01254

    Y=4.10 mm, ~ 0.25 ct

  • Type Ia Modified Brilliant {100} – P01026

    Y=3.00 mm, ~ 0.10 ct

  • Type Ia Modified Brilliant {Any} – P01255

    Y=4.40 mm, ~ 0.30 ct

  • Type Ia Modified Brilliant {100} – P01033

    Y=4.40 mm, ~ 0.30 ct

  • Type Ia Modified Brilliant {Any} – P01256

    Y=4.60 mm, ~ 0.35 ct

  • Type Ia Modified Brilliant {100} – P01034

    Y=4.60 mm, ~ 0.35 ct

Perforation

  • Partial Perforation

    Perforated / Partial perforated anvils

Patterning

  • Patterning

    Diamond anvils for electrical transport measurements

NPD

  • NPD

    Nano Polycrystalline Diamond

MINI AND MAXI

  • Type Ia, Boehler Almax Design; X=1.00 mm, P01942

    Miniature Boehler-Almax diamond anvil

  • Type Ia, Boehler Almax Design; X=1.25 mm

    Miniature Boehler-Almax diamond anvil

  • Type IIa, Maxi Synthetic CVD diamond anvil, X=8.00 mm

    Very large diamond anvils